Attributes
Productgroup ID |
2 |
Force F |
1000N |
Length [L] |
410mm |
Compression load [Fmax] |
1000N |
Tilting torque [My] |
125Nm |
Tensile load [Fmax] |
500N |
Tilting torque [Mx] |
300Nm |
Speed |
25mm/s |
Maximum load version [Fmax] |
1000N |
Weight |
9.500kg |
- Three lifting modules with different maximum lifting and pressure forces as well as lifting velocities for the continuous height adjustment of workplaces even under high loads.
- Three lifting lengths per variant
- Attachment by means of mounting plates at the face sides or using the integrated 10 mm slot
- Incl. Connection cable; cable length: ~2m
- Cable possible on the left or right side
- Diagonal cover cap prevents crushing risk
- All lifting modules are electrostatic discharge-enabled
- Mounting plates are connected in a conductive manner
- Attachment bracket set suitable for F1000, F1600 or F3200 lifting modules for lateral profile attachment (grid dimension 45mm)
- Notice: According to DIN EN 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements - 15.1 Sockets for accessories, the following applies: If the machinery or its associated equipment is equipped with outlets intended for accessories (e.g. hand-held power-operated tools, test equipment), the following shall apply:[...]- circuits supplying outlets with a rated current not exceeding 20 A shall be additionally protected by a residual current device (RCD) with a rated differential current of ≤ 30 mA.
- Note: According to IEC 60204-1:2016 - 15 Socket-outlets and lighting - Socket-15.1 outlets for accessories: Where the machine or its associated equipment is provided with socket-outlets that are intended to be used for accessory equipment (for example hand-held power tools, testequipment), the following apply:[…] – circuits supplying socket-outlets with a current rating not exceeding 20 A shall be provided with residual current protection (RCDs) with a rated operating current not exceeding 30 mA. - Notice: According to DIN EN 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements - 15.1 Sockets for accessories, the following applies: If the machinery or its associated equipment is equipped with outlets intended for accessories (e.g. hand-held power-operated tools, test equipment), the following shall apply:[...]- circuits supplying outlets with a rated current not exceeding 20 A shall be additionally protected by a residual current device (RCD) with a rated differential current of ≤ 30 mA.
Lifting module F1000-LIFT410MM
Three lifting modules with different maximum lifting and pressure forces as well as lifting velocities for the continuous height adjustment of workplaces even under high loads., Three lifting lengths per variant, Attachment by means of mounting plates at