ROCKER WI/M

Suitable for use in an EPA, , Suitable for mounting on an ST 2/… section with a profile width of 45 mm or an ST 2/…-H section with a profile width of 50 mm, For area monitoring, For workpiece pallet recognition, For accumulation pressure control, Simple a / Material Number:3842530797

ROCKER WI/M

Material #3842530797

Request Quote

Attributes

Productgroup ID 2
Monitoring range 60mm
Dry room <1
ESD yes
Weight 0.148kg
Scope of delivery Including fastening material for installation on ST 2/... conveyor section or BS 2/... belt section.
Recommended accessories Pneumatic cylinder switch
Recommended accessories Pneumatic cylinder switch
  • For area monitoring
  • For workpiece pallet recognition
  • For accumulation pressure control
  • Simple and compact construction
  • Suitable for mounting on an ST 2/… section with a profile width of 45 mm or an ST 2/…-H section with a profile width of 50 mm
  • n.a.
  • Suitable for use in an EPA
  • - n.a.
Rocker WI/M
Suitable for use in an EPA, , Suitable for mounting on an ST 2/… section with a profile width of 45 mm or an ST 2/… H section with a profile width of 50 mm, For area monitoring, For workpiece pallet recognition, For accumulation pressure control, Simple a

Rocker WI/M

1) Conveying level
2) Limit stop not activated
3) Limit stop activated

Rocker WI/M

The WI/M rocker cannot be used as a stop for workpiece pallets arriving from the transverse conveyor. In addition to this, a stop or damper that corresponds to the weight of the workpiece pallet must be installed to absorb the impact of the stop.

The pneumatic cylinder switch directly converts the slide activation into a pneumatic signal. Simple, purely pneumatic accumulation pressure regulation can be established in conjunction with a VE 2 stop gate.

Rockers are used for the following areas:

For area monitoring As a stop for transverse conveying of workpiece pallets For workpiece pallet recognition

 

Depending on the desired function, WI/M, WI 2/… rockers should be fitted with one or two sensors.

Installation locations on ST 2/… or ST 2/…-H

No.

3842530797

Cleanroom class

ISO class 7

Dry room

r.F.

%

<1

Monitoring range

mm

60,0

Request Quote