STOP GATE VE 2/S

, Pneumatic stop gate, Used on sections with reversible operation, Pressure must not be exerted on VE 2/S by pallets traveling in reverse / Material Number:3842515844

STOP GATE VE 2/S

Material #3842515844

Request Quote

Attributes

Productgroup ID 2
Workpiece pallet total weight [mG] 140kg
Operating temperature [T] max 0 ... +60 °C
Pneumatic straight connection [Ø] 4mm
required compressed air connection [pmax] 6bar
required compressed air connection [pmin] 4bar
Weight 0.375kg
Notice High-temperature stop gate on request
Nominal speed 6,9,12,15,18
Scope of delivery Incl. all fastening material to mount on ST 2/... conveyor section,Pneumatic elements
Workpiece pallet total weight [mG] mult 140,90,70,50,30
Delivery information Fully assembled
Recommended accessories VE 2/RS Return Stop,Switch bracket SH 2/...,Position sensor
Material information Housing: PA 6,Stop cam: PA 66
  • Pneumatic stop gate
  • Used on sections with reversible operation
  • Pressure must not be exerted on VE 2/S by pallets traveling in reverse
  • n.a.
  • - n.a.
VE 2/S Stop Gate
, Pneumatic stop gate, Used on sections with reversible operation, Pressure must not be exerted on VE 2/S by pallets traveling in reverse

Switch Bracket

Switch Bracket

Stop gate position sensor

Stop gate position sensor

For retrofitting on the VE 2, VE 2/M, VE 2/L and VE 2/S stop gates Upper and lower position sensing possible, only suitable for upper position sensing with VE 2/S

CAD data

VE 2/RS Return Stop

VE 2/RS Return Stop

Spring-loaded safety catch Can be used on the left or right

Assembly instructions

CAD data

Condition of Delivery

Fully assembled

Scope of delivery

Incl. all fastening material to mount on ST 2/... conveyor section
Pneumatic elements

Opening and shutting times

L = Hose length
1 Close
2 Open 4 bar

VE 2/S Stop Gate

Note: Safe transition from both directions is possible by actively (pneumatically) opening the safety catch.

Stops one or more accumulating workpiece pallets at the defined stop surface of the workpiece pallet. The VE 2/S can only stop workpiece pallets coming from one direction. When the pressure is released, the stop gate is closed by a spring and the workpiece pallet is stopped. Two VE 2/S stop gates are needed to stop pallets coming from both directions, since pressure must not be exerted on the stop gate by pallets traveling in reverse. Mounted inside the tracks, directly on the conveyor section.

Circuit diagram

1 not included in the scope of delivery

No.

3842515844

Max. total weight of workpiece pallet

mG

kg

140 kg

Operating temperature 1)

T

°C

0 ... +60

Material specification

Housing: PA 6
Lug cam: PA 66

Required compressed air connection

p

bar

4 ... 6 bar

Pneumatic push-in fitting

Ø

mm

4 mm
1) High-temperature stop gate on request

Permissible accumulation load

mG

vN

kg

m/min

140
90
70
50
30
6
9
12
15
18

Request Quote

How to Find Us

If you have any questions, just fill in the contact form, and we will answer you shortly. If you are living nearby, come visit us.

Headquarters

1505 W. Hamlin Road
Rochester Hills, MI 48309

Phone
248-584-5600
Fax
248-584-1117

West Michigan Office

Phone
269-381-1285
Fax
269-381-1379

Have questions?